| Product brand name | SIRIUS |
| Product designation | power contactor |
| General technical data | |
| Size of contactor | S0 |
| Degree of pollution | 3 |
| Protection class IP | |
| on the front | IP20 |
| of the terminal | IP00 |
| Mechanical service life (switching cycles) | |
| of contactor typical | 10 000 000 |
| of the contactor with added electronicscompatible auxiliary switch block typical | 5 000 000 |
| of the contactor with added auxiliary switch block typical | 10 000 000 |
| Reference code acc. to DIN EN 81346-2 | Q |
| Ambient conditions | |
| Installation altitude at height above sea level | |
| maximum | 2 000 m |
| Ambient temperature | |
| during operation | 25 ... +60 °C |
| Main circuit Number of poles | |
| Number of poles for main current circuit | 3 |
| Number of NO contacts for main contacts | 3 |
| Number of NC contacts for main contacts | 0 |
| Operating current | |
| at AC-1 at 400 V | |
| — at ambient temperature 40 °C rated value | 40 A |
| at AC-1 | |
| — up to 690 V at ambient temperature 40 °C rated value | 40 A |
| — up to 690 V at ambient temperature 60 °C rated value | 35 A |
| at AC-3 | |
| — at 400 V rated value | 17 A |
| at AC-4 at 400 V rated value | 15.5 A |
| Operating current | |
| at 1 current path at DC-1 | |
| — at 24 V rated value | 35 A |
| — at 110 V rated value | 4.5 A |
| with 2 current paths in series at DC-1 | |
| — at 24 V rated value | 35 A |
| — at 110 V rated value | 35 A |
| with 3 current paths in series at DC-1 | |
| — at 24 V rated value | 35 A |
| — at 110 V rated value | 35 A |
| Operating current | |
| at 1 current path at DC-3 at DC-5 | |
| — at 24 V rated value | 20 A |
| — at 110 V rated value | 2.5 A |
| with 2 current paths in series at DC-3 at DC-5 | |
| — at 24 V rated value | 35 A |
| — at 110 V rated value | 15 A |
| with 3 current paths in series at DC-3 at DC-5 | |
| — at 24 V rated value | 35 A |
| — at 110 V rated value | 35 A |
| Operating power | |
| at AC-1 | |
| — at 400 V rated value | 23 kW |
| at AC-2 at 400 V rated value | 7.5 kW |
| at AC-3 | |
| — at 400 V rated value | 7.5 kW |
| — at 500 V rated value | 10 kW |
| — at 690 V rated value | 11 kW |
| Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor | 0.9 W |
| Control circuit/ Control | |
| Type of voltage of the control supply voltage | DC |
| Control supply voltage at DC | |
| rated value | 24 V |
| Operating range factor control supply voltage rated value of magnet coil at DC | |
| initial value | 0.8 |
| Full-scale value | 1.1 |
| Closing power of magnet coil at DC | 5.4 W |
| Holding power of magnet coil at DC | 5.4 W |
| Auxiliary circuit | |
| Number of NC contacts for auxiliary contacts | |
| instantaneous contact | 0 |
| Number of NO contacts for auxiliary contacts | |
| instantaneous contact | 0 |
| Operating current at AC-12 maximum | 10 A |
| Operating current at AC-15 | |
| at 230 V rated value | 6 A |
| at 400 V rated value | 3 A |
| Operating current at DC-12 | |
| at 60 V rated value | 6 A |
| at 110 V rated value | 3 A |
| at 220 V rated value | 1 A |
| Operating current at DC-13 | |
| at 24 V rated value | 10 A |
| at 60 V rated value | 2 A |
| at 110 V rated value | 1 A |
| at 220 V rated value | 0.3 A |
| Contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
| Short-circuit protection | |
| Design of the fuse link | |
| for short-circuit protection of the main circuit | |
| — with type of coordination 1 required | fuse gL/gG: 63 A |
| — with type of assignment 2 required | fuse gL/gG: 25 A |
| for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A |
| Installation/ mounting/ dimensions | |
| Mounting type | screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 |
| Side-by-side mounting | Yes |
| Height | 85 mm |
| Width | 45 mm |
| Depth | 101 mm |